| Electrical Specifications |
| Maximum voltage to earth ground |
1000 V |
| Battery type |
AA alkaline IEC/EN LR6 (x4) |
| Battery life |
More than 15 hours* |
| * In Ground Resistance measurement mode, with backlight turned off, and RF mode turned off |
| Frequency range |
40 Hz to 1 kHz |
| Ingress protection |
IEC/EN 60529: IP30 with jaw closed |
| LCD |
Digital reading |
9999 counts |
| Refresh rate |
4 per second |
| Operating temperature |
-10 °C to + 50 °C |
|
| Storage temperature |
-20 °C to + 60 °C |
| Operating humidity |
Non condensing (<10 °C) (< 50 °F) |
| ≤90% RH (at 10 °C to 30 °C [50 °F to 86 °F]) |
| ≤75% RH (at 30 °C to 40 °C [86 °F to 104 °F]) |
| ≤45% RH (at 40 °C to 50 °C [104 °F to 122 °F]) |
| (Non condensing) |
| Operating altitude |
2000 m (6561 feet) |
| Storage altitude |
12 000 m (39,370 feet) |
| Reference temperature |
23 °C ±5 °C (73 °F ±9 °F) |
| Temperature coefficient |
0.15% x (specified accuracy)/ °C (<18 °C or >28 °C [<64.4 °F or >82.4 °F]) |
| Overload indication |
OL |
| Data logging capacity |
Minimum of 32,760 measurements |
| Data logging interval |
1 second to 59 minutes and 59 seconds |
| Display reading specification with standard loop resistance |
| Input (Ω) |
Minimum |
Maximum |
| 0.474 |
0.417 |
0.531 |
| 0.5 |
0.443 |
0.558 |
| 10 |
9.55 |
10.45 |
| 100 |
96 |
104 |
| Safety |
| General |
IEC/EN 61010-1: Pollution Degree 2 IEC/EN 61557-1 |
| Measurement |
IEC/EN 61010-2-032: CAT IV 600 V / CAT III 1000 V |
| Current clamp for leakage current measurements |
IEC/EN 61557-13: Class 2, ≤30 A/m |
| Resistance to earth |
IEC/EN 61557-5 |
| Effectiveness of thepProtective measures |
IEC/EN 61557-16 |
| Electromagnetic compatibility (EMC) |
International |
IEC/EN 61326-1: Portable Electromagnetic Environment |
| CISPR 11: Group 1, Class B, IEC/EN 61326-2-2 |
| Korea (KCC) |
Class A equipment (Industrial Broadcast & Communications Equipment) |
| USA (FCC) |
47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103 |
| Wireless Radio |
| Frequency range |
2412 MHz to 2462 MHz |
| Output power |
<10 mW |
| Radio frequency certification |
FCC ID:T68-FBLE IC:6627A-FBLE |
| General Specifications |
| Conductor size |
40 mm (1.57 in) approximately |
| Dimensions (L x W x H) |
283 x 105 x 48 mm (11.1 x 4.1 x 1.9 in) |
| Weight |
880g (31 oz) |
| Warranty |
One year |
| Earth Ground Loop Resistance |
| Range |
Accuracy1 ± (% of reading + Ω) |
| 0.025 Ω to 0.249 Ω |
1.5% + 0.02 Ω |
| 0.250 Ω to 0.999 Ω |
1.5% + 0.05 Ω |
| 1.000 Ω to 9.999 Ω |
1.5% + 0.10 Ω |
| 10.00 Ω to 49.99 Ω |
1.5% + 0.30 Ω |
| 50.00 Ω to 99.99 Ω |
1.5% + 0.50 Ω |
| 100.0 Ω to 199.9 Ω |
3.0% + 1.0 Ω |
| 200.0 Ω to 399.9 Ω |
5.0% + 5.0 Ω |
| 400 Ω to 599 Ω |
10.0% + 10 Ω |
| 600 Ω to 1500 Ω |
20.00% |
| 1 Loop resistance with no inductance, conductor centered and perpendicular to jaw |
| Earth ground leakage current mA |
| Autorange 50/60 Hz, True rms, crest factor CF ≤3 |
| Range |
Resolution |
Accuracy1 ± (% of reading + mA) |
| 0.200 mA to 3.999 mA |
1 μA |
2.0% + 0.05 mA |
| 4.00 mA to 39.99 mA |
10 μA |
2.0% + 0.03 mA |
| 40.0 mA to 399.9 mA |
100 μA |
2.0% + 0.3 mA |
| 0.400 A to 3.999 A |
1 mA |
2.0% + 3 mA |
| 4.00 A to 39.99 A |
10 mA |
2.0% + 30 mA |
1 Applies to signal frequency
- 40 Hz to 1 kHz with filter set to OFF
- 40 Hz to 70 Hz with filter se to ON
|
Reviews