FLUKE 568 Infrared Thermometer

99,362.00

Description

Key features

  • Combines the functionality of both contact and non-contact thermometers in a single device
  • Capable of accurately measuring a wide temperature range, from -40°C to 800°C (-40°F to 1472°F), with precision up to +1.0°C or +1.0% of the reading (whichever is greater)
  • Boasts a robust, ergonomic design built to withstand challenging industrial, electrical, and mechanical settings
  • Provides an impressive distance-to-spot ratio of 50:1, ensuring accurate measurements from a safe distance
  • Compatible with the majority of K-type thermocouples, offering versatility and convenience

Specifications: 568 Contact & Infrared Temperature Gun

Product Specifications
Infrared temperature range -40°C to 800°C (-40°F to 1472°F)
Infrared accuracy < 0°C (32°F): ±(1.0°C (±2.0°F) + 0.1°/1°C or°F);
> 0°C (32°F): ±1% or ±1.0°C (±2.0°F), whichever is greater
Display resolution 0.1°C / 0.1°F
Infrared spectral response 8 µm to 14 µm
Infrared response time < 500 msec
Thermocouple Type-K input temperature range -270°C to 1372°C (-454°F to 2501°F)
Thermocouple Type-K input accuracy -270°C to -40°C ±(1°C + 0.2°/1°C) (-454°F to -40°F: ±(2°F + 0.2°/1°F))
-40°C to 1372°C ±1% or 1°C (-40°F to 2501°F: ±1% or 2°F), whichever is greater
D:S (distance to measurement spot size) 50:1
Laser sighting Single-point laser < 1 mw output Class 2 (II) operation, 630 nm to 670 nm
Minimum spot size 19 mm (0.75 in)
Emissivity adjustment By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01
Data storage with date/time stamp 99 points
PC interface and cable USB 2.0 with FlukeView® Forms software
Hi/Low alarms Audible and two-color visual
Min/Max/Avg/Dif Yes
Display Dot matrix 98 x 96 pixels with function menus
Backlight Two levels, normal and extra bright for darker environments
Trigger lock Yes
Switchable Celsius and Fahrenheit Yes
Power 2 AA/LR6 Batteries and USB when used with a PC
Battery life If used continuously Laser and backlight on,12 hours; laser and backlight off, 100 hours
Operating temperature 0°C to 50°C (32°F to 122°F)
Storage temperature -20°C to 60°C (-40°F to 140°F)
Bead thermocouple Type-K range -40°C to 260°C (-40°F to 500°F)
Bead thermocouple Type-K accuracy ±1.1°C (2.0°F) from 0°C to 260°C (32°F to 500°F), typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F)